Enclosure Heaters for Electrical Cabinets

Harmful condensation can easily form when the internal temperature of control cabinets, racks, and technical installation spaces is too low. Anssin’s PTC heaters and resistance heaters heat control cabinets. Rack heaters with fans enhance convection, delivering warm air to every corner more quickly.

Compact options
For limited panel space

DIN rail models
For modular cabinet layouts

Fan heating
For active air circulation

01

Reduce condensation risk

Support cabinet temperature above critical cold conditions.

02

Choose the heat paths

Natural convection or fan assisted distribution.

03

Plan the installation

Match power, mounting and clearance to the panel.

China leading heater supplier - Anssin

Heaters are the preferred tool for preventing condensation inside control cabinets. Heating the air inside the cabinet avoids temperature fluctuations and maintains a constant relative humidity, thus protecting electrical and electronic components from damage caused by condensation moisture and preventing short circuits.

As a pioneer in cabinet heaters, Anssin offers semiconductor heaters and fan heaters. RCE 016, RC 016, HGK 047, HG 140, CS060, and CSF060 are semiconductor heaters with heating power ranging from 5W to 150W. Among them, CS060 and CSF060 are touch-safe heaters, providing protection against electric shock and thermal insulation.

HV 031 / HVL 031, HGL 046, CS 028 / CSL 028, CR 027, and CR 130 are fan heaters with heating power ranging from 100W to 950W, with CR130 having the highest power at 950W.

CABINET HEATING IN OPERATION ● SIMULATING
CABINET AIR
15.3 °C
COLDEST SURFACE
12.3 °C
DEW POINT
13.0 °C
COLD SURFACE
HEAT WARMS THE AIR AND
NEARBY SURFACES
↑ ↑ ↑
HEATER
● Condensation risk: surface below dew point HEATER ON
When a surface is colder than the dew point, moisture can condense. Heating helps raise its temperature.
Illustrative temperatures and switching points; not model specifications.

Anssin Heater Range

Browse the Anssin heater range; if the model you need is not listed, please contact us for further information.

RCE 016 / RC 016

The RCE 016 and RC 016 are compact heaters. These small heaters are specifically designed for electrical environments where space is limited. The RCE series is available with power ratings of 5 W or 9 W, while the RC series offers power ratings of 8 W, 10 W, or 13 W.

PTC HEATER

HGK 047

10–30 W PTC heater family for cabinet layouts where a small DIN rail unit is useful.

Semiconductor heater HG140

HG 140

Aluminum profile heater family listed from 15 to 150 W. Its vertical mounting arrangement supports upward airflow.

TOUCH-SAFE HEATER CS60

CS 060 / CSF 060

50–150 W enclosed PTC heater family. CSF adds a preset thermostat for a defined switching arrangement.

SPACE-SAVING FAN HEATER HV 031

HV 031 / HVL 031

100–400 W family. HV is supplied without a fan but requires one in operation; HVL includes a fan.

COMPACT FAN HEATER HGL 046

HGL 046

250 or 400 W fan heater family for active warm air circulation in electrical enclosures.

COMPACT SEMICONDUCTOR FAN HEATER CS 028

CS 028 / CSL 028

Compact 150 W and larger 250 or 400 W variants, with different body sizes and airflow arrangements.

Semiconductor Fan Heater CR027

CR 027

Features a built-in adjustable thermostat. Depending on the voltage and frequency, the power output can reach up to 650 W.

COMPACT HIGH-PERFORMANCE FAN HEATER CR 130

CR 130

950 W fan heater shown with thermostat or preset hygrostat versions

Key Features of ANSSIN Heater

PTC elements

Heat output changes with operating conditions; the element’s self limiting behavior is separate from cabinet temperature control.

Airflow

Choose a fan-assisted model when warm air needs to reach more of the enclosure. For a small, localized area, a heater without a fan may be sufficient.

Temperature Control

Choose a heater with integrated control if you need a compact assembly. Choose external thermostat control when the switching point and sensor position need to be set separately.

Mounting Method

Choose the mounting option that fits the enclosure layout. Allow space around the heater and air outlet according to the selected model’s installation instructions.

Applications Of Enclosure Heaters

AUTOMATION

PLC and drive cabinets

Provide heat during shutdown periods when equipment no longer warms the enclosure.

DISTRIBUTION

Electrical switchboards

Help manage low temperature and condensation risk around installed components.

OUTDOOR EQUIPMENT

Utility and communication cabinets

Support the cabinet thermal design through cold nights and seasonal changes.

LARGER ENCLOSURES

Air circulation projects

Use fan heating when heat must be distributed beyond a small local area.

OEM ASSEMBLIES

Repeat panel builds

Specify the same heater variant, supply and control arrangement across an equipment series.

Benefits of using a Heater

Protect idle equipment

Supplement the heat lost when drives, power supplies or other equipment stop operating.

Warm more of the cabinet

Fan models help move heated air into spaces that local convection may reach slowly.

Fit the panel layout

Choose among compact units, slim profiles and fan housings according to available space.

Repeat a control setup

Preset and integrated control versions can simplify a defined configuration across repeated builds.

BUYER CHECKLIST

What to confirm before ordering

Heater selection starts with the cabinet’s cold condition. Use enclosure surface area, material, insulation, target temperature difference and internal heat during operation and shutdown to estimate heat demand.

Next choose the way heat will spread, then check supply, starting current, mounting orientation and free space above the heater. A wattage printed without its temperature and voltage conditions is not a complete comparison.

01

Describe the enclosure

Dimensions, material, installation location and lowest ambient temperature.

02

State the heat requirement

Desired minimum internal temperature and whether equipment generates heat when idle.

03

Choose the air movement

Natural convection for local heating or a fan arrangement for active circulation.

04

Check electrical fit

Supply voltage, AC/DC, power, starting current and required control method.

05

Check mechanical fit

DIN or screw mounting, body dimensions, orientation and outlet clearance.

FAQ

Common buyer questions.

For distributors, importers, contractors, project buyers, manufacturers and OEM teams.

It adds heat inside an electrical cabinet to support low temperature operation and reduce condensation risk. It is designed for equipment enclosures, not room heating.

Estimate heat loss from the cabinet’s effective surface area, material and required temperature difference. Include the reduced internal heat during shutdown. Compare candidates at the same stated voltage and ambient conditions.

A convection heater depends on rising warm air. A fan heater actively pushes air through the cabinet, which can help distribute heat over a larger area.

PTC behavior changes the element’s power response as it warms. A thermostat is still useful when the cabinet needs an on and off temperature setpoint. Some heater variants include preset or adjustable control.

No. Heating can reduce condensation risk by raising temperature, but it does not remove water from the enclosure. Sealing and moisture entry still matter.

Many units are intended for low vertical installation with clear air inlet and outlet paths. Use the selected model’s installation drawing for its actual mounting position and clearance.

Contact Us

Request an enclosure heater quote

Share the series or cabinet conditions, supply voltage, quantity and delivery market so Anssin can respond with a matching model and current documentation.

OEM / ODM Distribution & importing Commercial supply

Send Your Inquiry Today

We Respond Within 10 hrs. or Less.

Ask For a Quote

We Respond Within 10 hrs. or less.

Ask For a Quote

We Respond Within 10 hrs. or less.

Ask For A Quick Quote

We will contact you within 1 working day,please wait patiently.