Enclosure Heaters for Electrical Cabinets
Harmful condensation can easily form when the internal temperature of control cabinets, racks, and technical installation spaces is too low. Anssin’s PTC heaters and resistance heaters heat control cabinets. Rack heaters with fans enhance convection, delivering warm air to every corner more quickly.
Compact options
For limited panel space
DIN rail models
For modular cabinet layouts
Fan heating
For active air circulation
Reduce condensation risk
Support cabinet temperature above critical cold conditions.
Choose the heat paths
Natural convection or fan assisted distribution.
Plan the installation
Match power, mounting and clearance to the panel.
China leading heater supplier - Anssin
Heaters are the preferred tool for preventing condensation inside control cabinets. Heating the air inside the cabinet avoids temperature fluctuations and maintains a constant relative humidity, thus protecting electrical and electronic components from damage caused by condensation moisture and preventing short circuits.
As a pioneer in cabinet heaters, Anssin offers semiconductor heaters and fan heaters. RCE 016, RC 016, HGK 047, HG 140, CS060, and CSF060 are semiconductor heaters with heating power ranging from 5W to 150W. Among them, CS060 and CSF060 are touch-safe heaters, providing protection against electric shock and thermal insulation.
HV 031 / HVL 031, HGL 046, CS 028 / CSL 028, CR 027, and CR 130 are fan heaters with heating power ranging from 100W to 950W, with CR130 having the highest power at 950W.
NEARBY SURFACES
Anssin Heater Range
Browse the Anssin heater range; if the model you need is not listed, please contact us for further information.
RCE 016 / RC 016
The RCE 016 and RC 016 are compact heaters. These small heaters are specifically designed for electrical environments where space is limited. The RCE series is available with power ratings of 5 W or 9 W, while the RC series offers power ratings of 8 W, 10 W, or 13 W.
HGK 047
10–30 W PTC heater family for cabinet layouts where a small DIN rail unit is useful.
HG 140
Aluminum profile heater family listed from 15 to 150 W. Its vertical mounting arrangement supports upward airflow.
CS 060 / CSF 060
50–150 W enclosed PTC heater family. CSF adds a preset thermostat for a defined switching arrangement.
HV 031 / HVL 031
100–400 W family. HV is supplied without a fan but requires one in operation; HVL includes a fan.
HGL 046
250 or 400 W fan heater family for active warm air circulation in electrical enclosures.
CS 028 / CSL 028
Compact 150 W and larger 250 or 400 W variants, with different body sizes and airflow arrangements.
CR 027
Features a built-in adjustable thermostat. Depending on the voltage and frequency, the power output can reach up to 650 W.
CR 130
950 W fan heater shown with thermostat or preset hygrostat versions
Key Features of ANSSIN Heater
PTC elements
Heat output changes with operating conditions; the element’s self limiting behavior is separate from cabinet temperature control.
Airflow
Choose a fan-assisted model when warm air needs to reach more of the enclosure. For a small, localized area, a heater without a fan may be sufficient.
Temperature Control
Choose a heater with integrated control if you need a compact assembly. Choose external thermostat control when the switching point and sensor position need to be set separately.
Mounting Method
Choose the mounting option that fits the enclosure layout. Allow space around the heater and air outlet according to the selected model’s installation instructions.
Applications Of Enclosure Heaters
PLC and drive cabinets
Provide heat during shutdown periods when equipment no longer warms the enclosure.
Electrical switchboards
Help manage low temperature and condensation risk around installed components.
Utility and communication cabinets
Support the cabinet thermal design through cold nights and seasonal changes.
Air circulation projects
Use fan heating when heat must be distributed beyond a small local area.
Repeat panel builds
Specify the same heater variant, supply and control arrangement across an equipment series.
Benefits of using a Heater
Protect idle equipment
Supplement the heat lost when drives, power supplies or other equipment stop operating.
Warm more of the cabinet
Fan models help move heated air into spaces that local convection may reach slowly.
Fit the panel layout
Choose among compact units, slim profiles and fan housings according to available space.
Repeat a control setup
Preset and integrated control versions can simplify a defined configuration across repeated builds.
BUYER CHECKLIST
What to confirm before ordering
Heater selection starts with the cabinet’s cold condition. Use enclosure surface area, material, insulation, target temperature difference and internal heat during operation and shutdown to estimate heat demand.
Next choose the way heat will spread, then check supply, starting current, mounting orientation and free space above the heater. A wattage printed without its temperature and voltage conditions is not a complete comparison.
Describe the enclosure
Dimensions, material, installation location and lowest ambient temperature.
State the heat requirement
Desired minimum internal temperature and whether equipment generates heat when idle.
Choose the air movement
Natural convection for local heating or a fan arrangement for active circulation.
Check electrical fit
Supply voltage, AC/DC, power, starting current and required control method.
Check mechanical fit
DIN or screw mounting, body dimensions, orientation and outlet clearance.
FAQ
Common buyer questions.
For distributors, importers, contractors, project buyers, manufacturers and OEM teams.
It adds heat inside an electrical cabinet to support low temperature operation and reduce condensation risk. It is designed for equipment enclosures, not room heating.
Estimate heat loss from the cabinet’s effective surface area, material and required temperature difference. Include the reduced internal heat during shutdown. Compare candidates at the same stated voltage and ambient conditions.
A convection heater depends on rising warm air. A fan heater actively pushes air through the cabinet, which can help distribute heat over a larger area.
PTC behavior changes the element’s power response as it warms. A thermostat is still useful when the cabinet needs an on and off temperature setpoint. Some heater variants include preset or adjustable control.
No. Heating can reduce condensation risk by raising temperature, but it does not remove water from the enclosure. Sealing and moisture entry still matter.
Many units are intended for low vertical installation with clear air inlet and outlet paths. Use the selected model’s installation drawing for its actual mounting position and clearance.
Contact Us
Request an enclosure heater quote
Share the series or cabinet conditions, supply voltage, quantity and delivery market so Anssin can respond with a matching model and current documentation.