Sensor Detectors Manufacturer

Anssin offers a range of sensor detectors for lighting control and security applications, including PIR motion sensors, radar sensors, sensor lamp holders, sensor lights and light control sensors. Certifications vary by model; contact us for the documents relevant to your selected product and market.

Ceiling & wall designs
Match the mounting position

Detection choices
Angle and distance by model

Light control
Motion or daylight based

01

Detection

Movement or ambient light

02

Coverage

Angle and range vary by model

03

Installation

Ceiling or wall designs

Motion and light control

Whether you’re protecting a small business, a large commercial property, or a high-security facility, you need reliable motion detectors to react instantly to intruders.

Anssin boasts a long patent history and award-winning performance in intrusion alarm systems. Our detectors are extremely reliable, offering excellent detection performance while virtually eliminating false alarms. Through continuous R&D investment, we ensure that the most advanced technology is applied to our devices. Our products are not only intelligent and reliable, offering best-in-class detection performance, but also easy to install and durable, reducing installation and maintenance costs.

MOTION → LIGHT ● SIMULATING
DETECTION AREA
◎PIR SENSOR
PERSON MOVING
→
✦ CONNECTED LIGHT
No movement detected Light off

Illustration only. Alarm mode shows a compatible external controller, not an alarm built into the sensor.

Anssin Sensor Detector Product Range

Please take a look at our products. You can compare the detection coverage and load ratings for each model.

Sensor detector SN05M-B

SN05M-B

360° detection · up to 8 m · max 200 W

PIR Motion Sensor ST11

SN11-W

180° detection · up to 12 m · max 400 W

Infrared motion sensor ST10F

ST10f

180° detection · up to 12 m · max 1200 W

Infrared motion sensor ST05B

SN05B

360° detection · up to 12 m · max 300 W

Digital infrared motion sensor ST09

ST09

180° detection · up to 12 m · max 1200 W

Infrared Sensor light Switch ST33

ST33

120° detection · up to 9 m · max 1200 W

Human body sensor switch ST41f

st41f

360° detection · up to 8 m · max 1200 W

Pir sensor detector ST12

st12

360° detection · up to 8 m · max 1200 W

Outdoor pir detector sensor ST15

SN15F-W

180° / 360° detection · up to 12 m · max 600 W

PIR Motion Sensor ST45B

st45b

360° detection · up to 8 m · max 800 W

ST42 Motion and light sensor recessed fixtype

st42

360° detection · up to 20 m · max 1000 W

Detector Switch Infrared ST46b

st46b

360° detection · up to 20 m · max 1000 W

Indoor motion detector ST300W

Light control sensor ST300-W

AC 110–130 V / 220–240 V · 1–9 hour timer · max 1300 W

Photocell sensor SN301 / 302 / 303

IP44 · AC 220–240 V, 50 Hz · 35.5 × 46 × 44.1 mm

Key Features

01

Detection angle and distance

The angle describes the area around the sensor; the distance describes how far movement may be detected. The range includes directional wall designs and 360° ceiling designs, with detection distances varying by model.

02

Motion or daylight response

PIR models respond to movement across their sensing field. Photocell and light control models respond to ambient light, so lights can operate according to the surrounding brightness.

03

Light level setting

On models with an adjustable light threshold, lighting can remain off when daylight is sufficient and switch on under the selected darker conditions.

04

Time delay

Selected motion models allow the connected light to remain on for a set period after the last detected movement. The ST300-W light control sensor has a separate 1–9 hour timer.

05

Load and supply ratings

Maximum connected load and operating voltage differ by model. These figures matter when pairing a sensor with an LED fixture or another electrical load.

06

Mounting and enclosure

Ceiling and wall housings cover different directions and installation layouts. For exposed locations, check the specific model’s IP rating and mounting requirements.

Applications of Sensor Detector

Motion and daylight sensors control compatible lighting in buildings, entrances and outdoor areas.

01 / SHARED SPACES

Corridors and stairwells

Switch lighting as people move through shared routes. Ceiling sensors can cover open landings, while directional wall sensors focus on an approach.

02 / ACCESS

Entrances and walkways

Detect someone approaching a doorway or path and switch a connected light.

03 / INTERIORS

Storage and utility rooms

Bring on lighting when someone enters a room used for short periods.

04 / EXTERIORS

Outdoor lighting

Use a suitable rated sensor to control lighting near exterior doors and service areas.

05 / DAYLIGHT CONTROL

Dusk-to-dawn lighting

Photocell models respond to ambient light where daylight-based switching is needed.

Benefits of using Sensor Detector

What automatic sensing can improve when the sensor and connected light are matched to the space.

01

Light when needed

Movement-triggered lighting helps people enter and pass through a space without searching for a switch.

02

Less unnecessary lighting

Timed shutoff can reduce the hours a light stays on after a space is empty. Actual savings depend on usage and settings.

03

Better visibility at entrances

A connected light can come on as someone approaches, making doors, steps and pathways easier to see.

04

Control suited to the space

Ceiling and wall designs let the detection field follow the room layout, while photocell models provide daylight-based switching.

BUYER CHECKLIST

Selection Guide

Start with the space and the connected light. Coverage diagrams and rated loads are model-specific, so the exact specification matters more than a category-wide maximum.

For a project inquiry, include the installation position, supply voltage, lamp type and wattage, detection area, exposure to moisture and required quantity.

01

Define the sensing task

Movement detection or ambient-light switching.

02

Choose the mounting position

Ceiling, wall, flush or outdoor mounting.

03

Map the coverage

Detection angle, distance and mounting height.

04

Check the electrical load

Supply voltage and the connected lamp’s type and power.

05

Check the environment

IP rating, ambient light setting and time delay.

FAQ

Common buyer questions.

For distributors, importers, contractors, project buyers, manufacturers and OEM teams.

A PIR sensor reacts to movement across its field. A photocell responds to the surrounding light level. Some lighting-control designs use both conditions.

No. A ceiling detector covers around its mounting point, while a wall detector can target an entrance or approach. The layout determines the better fit.

Published distance depends on the model and test conditions. Mounting height, movement direction, obstacles and temperature can affect detection in practice.

Use the LED-load rating stated for the specific model. A general wattage figure may apply to a different lamp type.

Share the mounting position, supply voltage, lamp type and load, required coverage, indoor or outdoor exposure, model preference and quantity.

Contact Us

Request a Sensor Detector quote

Tell us the sensing task, installation location and connected load. We can match the requirement to a suitable model.

OEM / ODM Distribution & importing Commercial supply

Send Your Inquiry Today

We Respond Within 10 hrs. or Less.

Ask For a Quote

We Respond Within 10 hrs. or less.

Ask For a Quote

We Respond Within 10 hrs. or less.

Ask For A Quick Quote

We will contact you within 1 working day,please wait patiently.